Calibrator modes

Calibrator provides two modes: Standard and Expert. You can perform all essential calibration tasks in Standard mode. Expert mode offers additional options to print a test page and to view measurement data.

  • Print Pages - Enables you to see the effects of the new calibration in printed output. With the Print Pages option, you can print Comparison Pages showing the results of the new measurements with any profile associated with the currently selected calibration set. You can create a custom Comparison Page and save it as a PostScript or Encapsulated PostScript (EPS) file called CALIB.PS. Next, print the file to the Hold queue of the Fiery print controller. You can also create a CALIB.PS file by renaming any job in the Hold queue.

  • View Measurements - Enables you to examine the measurement data. With the View Measurements option, you can view the current set of measurements as a table or graph that shows both the measurements and the target curves.

When more than one profile uses the same target, an additional menu called Plot Against is displayed in the upper-right corner of the dialog box. It lists all output profiles that use that same calibration set. Selecting an output profile from this menu displays the target curves associated with that profile. If each output profile contains a unique calibration target, the curves displayed also change when you switch profiles.