View measurement results

After you measure a calibration page or import measurements, the measurement results are ready to be applied. Applying (saving) the measurement data overwrites the existing data. For color data, you can view the measurement data in a graph to check the data before applying it.

Measurement results are shown as a set of density curves for C, M, Y, and K. For comparison, the calibration target data is also shown as a set of thicker density curves in the same graph, and the maximum density values are compared numerically.

  1. After you have successfully measured the calibration page or imported measurements from a file, click View Measurements.
  2. To hide or show curves, click the icon next to the appropriate label:
    • Measured - Hides or shows the measured density curves.

    • Target - Hides or shows the target density curves.

    • Cyan, Magenta, Yellow, or Black - Hides or shows the measured and target density curves for the specific colorant.